• Model:
  • SIM-Q , SIM-Q LF
  • Request Code:
  • SIM-Q x-y z , SIM-Q LF x-y z
  • Company:
  • DEIF
  • Country:
  • Denmark

Selectable Insulation Monitor produced by DEIF company is used for supervision of the insulation resistance between an insulated voltage distribution network (IT network) and earth cable/safety cable. The instrument is applicable in conjunction with single phase networks and 3-phase networks with/without neutral for phase to phase voltages up to 690V AC. This type of insulation measurement is only carried out on AC networks where the neutral/star point of the generator or supply transformer is not earthed. An AC or DC auxiliary voltage is required for the in- strument. This may be selected independently of the monitored network, or the SIM-Q can be supplied by the monitored network; max. voltage for the supply is 480V. If the SIM-Q is supplied from a separate voltage source, the network can also be monitored in stand-by condition. Because of the measuring method used, the SIM-Q is able to measure the insulation correctly on an AC power network containing all kinds of loads, such as frequency converters (see the technical specifications for working frequency range), valves with rectifiers, thyristor controlled thrusters, switch mode power supplies, transformers, generators etc. In AC power network installations with frequency converters operating down to 5 Hz, the SIM-Q LF is the right choice. The main indicator is the instrument. Besides the instrument the SIM-Q is equipped with 3 LED indicators, 1 green and 2 red LEDs. Only the green indicator marked SUPERVISION is lit when the unit is connected to auxiliary supply and no insulation error is detected. The 2 red LED indicators marked +FAULT and -FAULT are illuminated, if an insulation error below the setpoint is detected. If a DC voltage occurs on the system together with an insulation error, the +FAULT or the -FAULT LED is illuminated, indicating the polarity of the DC voltage. This function will indicate the reason for the insulation error. The range from the lowest permissible insulation resistance to zero is marked with red. a standard 1000...0 kΩ scale with a standard red section from 11 to 0 kΩ. Also, a standard 10...0 MΩ scale with a standard red section from 0.44 to 0 MΩ. Bornika is the exclusive agent of DEIF company in the fields of consultation, sales and distribution of power industry products including Selectable Insulation Monitor.

Selectable Insulation Monitor Specification

Operative voltage Auxiliary voltage: Select between: 24V DC ±25% <4 W or 100, 110, 127V AC or 220, 230, 240V AC or 400, 450, 480V AC ±20% 40...70 Hz, <4 VA
Relay Output By means of a built-in switch located under the rear cover the relay can be configured to either: NE : Recommended for alarm purposes. In case of an auxiliary supply drop-out the contact is immediately activated. It is recommended to supply the SIM-Q from a separate source, if this type is used. ND: Recommended for control purposes. Also recommended if the auxiliary supply for the SIM-Q is taken from the same power system under supervision.
Input Range 0 to 1000 kΩ 0 to 10 MΩ
Dimension 96x96mm
Mounting type Flush mounting
IP Instrument: IP52. Electronics: IP20. Terminals: IP20. To IEC 529 and EN 60529
Measured Quantity Monitoring of insulation resistance
Approximate Weight 0.390 kg

Selectable Insulation Monitor Catalogs

Download Catalog : Insulation monitor, SIM-Q/SIM-Q LF 688 KB

Selectable Insulation Monitor More Description

Ordering code Ordering code SIM-Q x-y z , SIM-Q LF x-y-z : x: Low range voltage include : 100 , 220 and 400 VAC y : High range voltage include : 127 , 240 and 480 VAC. *Note : above voltages is correspond together . z : AC : voltage type * note : ordering code with DC auxiliary supply described as follows SIM-Q 24VDC , SIM-Q LF 24VDC

Leakage capacitors Max to 500 microF

Selectable Insulation Monitor Price

Please call ...

Applications

  1. Refinery
  2. Electronics industry
  3. Power industry
  4. Packaging Industry
  5. Petrochemical industry
  6. Automotive industry
  7. Marine and shipbuilding industry
  8. Road Construction industry
  9. Food industry
  10. Telecommunications industry
  11. Military and defense industry
  12. Oil and gas industry
  13. Power Plant industry
  14. Panel building companies
  15. Steel industry
  16. Instrumentation Companies
  17. Textile industry
  18. Education and Laboratory industry
  19. Publishing and Printing industry
  20. Rubber and plastics industry
  21. Manufacturing of metal products
  22. Machinery and equipment industry
  23. Industrial machinery, electrical appliances
  24. Manufacturing of radio, television, communication devices and gauging devices
  25. Measurement devices, medical and optical industry
  26. Sugar industry
  27. Materials and pharmaceutical products industry
  28. Chemical products industry
  29. The computer industry and related activities
  30. Engineering services industry
  31. Building industry
  32. Tile and Ceramic industry
  33. Cement, lime and plaster industry
  34. The banking industry and credit institutions
  35. Transport, warehousing and communications industry
  36. Railway and subway industry
  37. Meteorological industry
  38. Science and Technology Education
  39. Aerospace Industry
  40. Automation industry
  41. Photography and video recording
  42. Charger, inverter and converters manufacturers
  43. Cathodic protection companies
  44. Transformer manufacturing companies

COMMENTS