On the base of standard, installed arrestor gap between Class C and Class D must not be less than 5 meters. Observe the distance, the problems that are created by the State Board for fixing, “Combination arrestor C+D“ can be used. Bornika is the exclusive agent of OBO Bettermann in the fields of consulation, sales and distribution of power industry products including Combination Class C+D, Type II+III.
Protection against lightning and severe vibration device, Class C + D , type II + III , high current conductivity and long life, with function display , suitable for TN, TT network systems , Arresting capacity to 10kA per pin (8/20) , With Maximum Continuous Operating Voltage (Uc=150V) , Appliction : industry , housing and device protection of rotary current sysrems .
Protection against lightning and severe vibration device, Class C + D , type II + III , high current conductivity and long life, with function display , suitable for TN, TT network systems , Arresting capacity to 10kA per pin (8/20) , With Maximum Continuous Operating Voltage (Uc=255V) , Appliction : industry , housing and device protection of rotary current sysrems .
Protection against lightning and severe vibration device, Class C + D , type II + III , high current conductivity and long life, with function display , suitable for TN, TT network systems , Arresting capacity to 10kA per pin (8/20) . Appliction : industry , housing and device protection of rotary current sysrems . On the base of standard, installed arrestor gap between Class C and Class D must not be less than 5 meters. Observe the distance, the problems that are created by the State Board for fixing, “Combination arrestor C+D“ can be used.
Protection against lightning and severe vibration device, Class C + D , type II + III , high current conductivity and long life, with function display , suitable for TN, TT network systems , Arresting capacity to 20kA per pin (8/20) , Appliction : industry , housing and device protection of rotary current sysrems . On the base of standard, installed arrestor gap between Class C and Class D must not be less than 5 meters. Observe the distance, the problems that are created by the State Board for fixing, “Combination arrestor C+D“ can be used.
Protection against lightning and severe vibration device, Class C + D , type II + III , high current conductivity and long life, with function display , Arresting capacity to 10kA per pin (8/20) . Appliction : industry , equipotential bonding and device protection in main and subdistributors . On the base of standard, installed arrestor gap between Class C and Class D must not be less than 5 meters. Observe the distance, the problems that are created by the State Board for fixing, “Combination arrestor C+D“ can be used.
Protection against lightning and severe vibration device, Class C + D , type II + III , high current conductivity and long life, with function display , Arresting capacity to 10kA per pin (8/20) , Appliction : industry , housing and device protection of rotary current sysrems . On the base of standard, installed arrestor gap between Class C and Class D must not be less than 5 meters. Observe the distance, the problems that are created by the State Board for fixing, “Combination arrestor C+D“ can be used.
Protection against lightning and severe vibration device, Class C + D , type II + III , high current conductivity and long life, with function display , suitable for TN, TT network systems , Arresting capacity to 10kA per pin (8/20) , Appliction : industry , equipotential bonding and device protection in main and subdistributors . On the base of standard, installed arrestor gap between Class C and Class D must not be less than 5 meters. Observe the distance, the problems that are created by the State Board for fixing, “Combination arrestor C+D“ can be used.
Protection against lightning and severe vibration device, Class C + D , type II + III , high current conductivity and long life, with function display , suitable for TN, TT network systems , Arresting capacity to 10kA per pin (8/20) . On the base of standard, installed arrestor gap between Class C and Class D must not be less than 5 meters. Observe the distance , the problems that are created by the State Board for fixing, “Combination arrestor C+D“ can be used.
SPD Surge protection device, Type 2+3 / Class II+III, 2 poles, (L-N-GND), 10 kA (8/20), 230 / 400 V, aerial.
Combined SPD, Type 2+3 / Class II+III, EMI filter, 2 poles, 20 A gL, 20 kA (8/20), 6 kV (Uoc), 120 / 208 V, with remote indication.
Combined SPD, Type 2+3 / Class II+III, 2 poles, 20 kA (8/20), 10 kV (Uoc), 230 Vac, 1 module.