Current Shunt

Visits : 736
Current Shunt

DC shunts convert high value current in DC circuits into proportional voltage drop (50mV/60mV/75mV/150mV) which can be connected of DC voltmeters to measure the high value current. Form A : Insulating base mounted shunts clamping to DIN mounting rail or wall mounting (upto 30A) without insulating base (31...150A) , High conductivity brass Form B : L-profile end blocks , High conductivity brass / copper Form C : High conductivity brass / copper Base material : Polycarbonate Accuracy class : Class 1, 0.5, 0.2 (Optional) Bornika is the exclusive agent of Ziegler, Lumel, Enerdis company in fields of consultation, sales and distribution of power industry products including DC Shunts .

Products

DC Shunts

Model: 50mV , 60mV , 75mV ,150mV Order code: 50mV , 60mV , 75mV ,150mV

DC shunts convert high value current in DC circuits into proportional voltage drop (50mV/60mV/75mV/150mV) which can be connected of DC voltmeters to measure the high value current.

Show Detail

Enerdis DC current shunt

Model: 76-2, 77-2, SHMI, SHEL, SHMO Order code: 76-2, 77-2, SHMI, SHEL, SHMO

Enerdis DC current shunt used for measuring high currents in DC networks. enerdis shunts are available in five following models: 76-2:with Eye connection, Eye connection on base 77-2: with Plate connection for busbar SHMI: with Screw, Eye and to block for busbar connection SHEL: with Direct connection to measuring component Enerdis DC shunts are available in 1A to 6000A with voltage drops: 50 mV - 60 mV - 100 mV - 150 mV - 200 mV - 300 mV - 1 V

Show Detail

DC Shunt

Model: B2 Order code: Shunt- B2 060 aaaaa b c dd e f

Measuring shunts B2 type are destined to extend measuring ranges of d.c. ammeters, wattmeters and electrodynamic or ferrodynamic counters which accuracy classes are: 1, 1.5, or 2.5

Show Detail

Shunt Resistor

Model: B3 Order code: Shunt- B3 150 aaaaa b c dd e f

Measuring shunts B3 type are destined to extend measuring ranges of d.c. ammeters, wattmeters and electrodynamic or ferrodynamic counters which accuracy classes are: 1, 1.5, or 2.5

Show Detail

LUMEL Shunt Resistor

Model: B4 Order code: Shunt- B4 050 aaaaa b c dd e f

Measuring shunts B4 type are destined to extend measuring ranges of d.c. ammeters, wattmeters and electrodynamic or ferrodynamic counters which accuracy classes are: 1, 1.5, or 2.5

Show Detail

DC Shunt Resistor

Model: B5 Order code: Shunt- B5 075 aaaaa b c dd e f

Measuring shunts B5 type are destined to extend measuring ranges of d.c. ammeters, wattmeters and electrodynamic or ferrodynamic counters which accuracy classes are: 1, 1.5, or 2.5

Show Detail

100 mV Shunt

Model: B6 Order code: Shunt- B6 100 aaaaa b c dd e f

Measuring shunts B6 type are destined to extend measuring ranges of d.c. ammeters, wattmeters and electrodynamic or ferrodynamic counters which accuracy classes are: 1, 1.5, or 2.5

Show Detail

Shunt Resistor

Model: Shunt Resistor Order code: Shunt Resistor Amps/mV

Shunts provide an accurate DC milivolt signal to drive moving-coil ammeters, overload protection and control units for higher ampere range. Shunt Resistors introduced by two generally type as 60 and 150 mV. Type 60 mV divided into A and B form. Also , Type 150mV divided into Three form as A , B and C.

Show Detail