These transducers are used for measuring several variables of an electrical power system simultaneously and converting them to 2 or 3 or 4 analog output, 2 or 4 digital output for signaling limitation, output simulator, output limiter and power measurement. The RS232/485 interface at the multi-transducers enables programming with the help of PC and Software and can also be used to initialize helpful ancillary functions. Bornika is the exclusive agent of Ziegler and Enerdis and agent of Contrel in the fields of consultation, sales and distribution of power industry products including Programmable Multi-Transducer.

Products

Programmable Dual output Transducer

Model: PI-102 Order code: PI-102

Programmable Dual output Transducer is purpose to electrically isolate input, outputs and power supply. The isolator fulfills all requirements and regulation concerning electromagnetic compatibility EMC and safety (IEC61326-1 and IEC 61010-1:2010). The device has one input and provides two independent outputs in an extremely small space.

Show Detail

Programmable Transducer

Model: M01 Order code: M01

Ziegler M01 Programmable Multi-Transducer and Transmitter are used for measuring several variables of an electrical power system simultaneously and for signaling limitation , output simulator , output limiter and power measurement . The RS232/485 interface at the multi-transducers enables programming with the help of PC and Software and can also be used to initialize helpful ancillary functions .

Show Detail

Ziegler M20 Programmable Transducer and Transmitter

Model: M20 Order code: M20

Ziegler M20 Programmable Multi-Transducer and Transmitter are used for measuring several variables of an electrical power system simultaneously and converting them to 2 analog output , without digital output for signaling limitation , output simulator , output limiter and power measurement . The RS232 interface at the multi-transducers enables programming with the help of PC and Software and can also be used to initialize helpful ancillary functions .

Show Detail

Ziegler M24 Programmable Multi-Transducer and Transmitter

Model: M24 Order code: M24

Ziegler M24 Programmable Multi-Transducer and Transmitter are used for measuring several variables of an electrical power system simultaneously and converting them to 2 analog output , 4 digital output for signaling limitation , output simulator , output limiter and power measurement . The RS-232 interface at the multi-transducers enables programming with the help of PC and Software and can also be used to initialize helpful ancillary functions .

Show Detail

Programmable Transducer

Model: M30 Order code: M30

Ziegler M30 Programmable Multi-Transducer and Transmitter are used for measuring several variables of an electrical power system simultaneously and converting them to 3 analog output , without digital output for signaling limitation , output simulator , output limiter and power measurement . The RS-232 interface at the multi-transducers enables programming with the help of PC and Software and can also be used to initialize helpful ancillary functions .

Show Detail

Ziegler M40 Programmable Transducer and Transmitter

Model: M40 Order code: M40

Ziegler M40 Programmable Multi-Transducer and Transmitter are used for measuring several variables of an electrical power system simultaneously and converting them to 4 analog output , without digital output for signaling limitation , output simulator , output limiter and power measurement . The RS-232/485 interface at the multi-transducers enables programming with the help of PC and Software and can also be used to initialize helpful ancillary functions .

Show Detail

Ziegler M42 Programmable Multi-Transducer and Transmitter

Model: M42 Order code: M42

Ziegler M42 Programmable Multi-Transducer and Transmitter are used for measuring several variables of an electrical power system simultaneously and converting them to 4 analog output , 2 digital output for signaling limitation , output simulator , output limiter and power measurement . The RS232 interface at the multi-transducers enables programming with the help of PC and Software and can also be used to initialize helpful ancillary functions .

Show Detail

Ziegler PRO-M Programmable Multi-Transducer

Model: PRO-M Order code: PRO-M

The Ziegler Pro M transducer is used to measure and convert parameter of Three-phase 3W/4W AC power network with balanced or unbalanced system . Measuring Input : AC Voltage/Current input signal , sine wave or distorted wave form . Analog Output : Analog output which can be set in between -20mA....20mA onsite .

Show Detail

Ziegler Pro-P Programmable Transducer and Transmitter

Model: Pro-P Order code: Pro-P

The Ziegler PRO - P transducer is used to measure and convert active, reactive, apparent power, Phase angle & Power Factor of a Single-phase or Three-phase AC system with balanced or unbalanced load into a proportional load independent DC current or voltage output signal .

Show Detail

Enerdis MICAR2 Digital Transducer ( Ethernet )

Model: MICAR2 Order code: MICAR2-Ethernet

MICAR2(Ethernet) Enerdis company is used for Connection on single-phase and three-phase networks ( 3 or 4 wires) , 32 measurable electrical values , Ethernet output , Configurable by software E.set via optical head , Mounting on DIN rail or plate mounting .

Show Detail

Enerdis MICAR2 Digital Transducer( RS485 )

Model: MICAR2 Order code: MICAR2-RS485

MICAR2(RS485) Enerdis company is used for Connection on single-phase and three-phase networks ( 3 or 4 wires) , 32 measurable electrical values , RS485 output , Configurable by software E.set via optical head , Mounting on DIN rail or plate mounting .

Show Detail

Multi-function digital transducer Triad2

Model: Triad2 Order code: T303, T304

Multi-function digital transducer type T303 with 3 analogue outputs and Type T304 with 4 analogue outputs for single-phase, split-phase and 3 or 4-wire balanced or unbalanced three-phase networks Quantities measured: Vac, Uac, Iac, P, Q, S, F, PF, phi, Cos phi, Tan phi, phiU, phiV Accuracy: Class 0.1 Voltage inputs: 480 (ph-ph) 1 MV (ph-ph) maximum primary voltage measured Current input: 1 A and 5 A 40,000 A maximum primary current measured Ratings of analogue outputs: