Single Phase Power Switching Supply PS1 - 2425 | ZAU PS1 - 2425

  • Model: PS1 - 2425
  • Request Code: PS1 - 2425
  • Company: Ziegler
  • Country: England
Single Phase  Power Switching Supply PS1 - 2425 | ZAU PS1 - 2425

Single phase switch- made power supply (SMPS) is used to produce electrical energy for one or more demanding loads. This equipment produced energy with high efficiency and low loss power. The output voltage of single phase power switching supply, type PS1 - 2425 is 24 volt dc and the output current is 25 A. It just can be supplied with both ac voltage and dc voltage. Single phase switch- made power supply type PS1 - 2425 has power boost and short circuit protection capability. In addition, this switching power supply has a relay to monitor the output voltage. Power boost feature allows the use of a smaller size instead big size units to power demanding loads such as motors, solenoid valves, lamps and other loads which needs high power sources. short circuit protection : - Manual Reset - Hiccup mode - Continuous mode the efficiency of the PS1 - 2425 model is up to 92% and the maximum power is 600 w. Bornika has the exclusive agent of Ziegler in the fields of consultation, sales and distribution of power industry products and switching power supplies in different voltage and power ranges.

Specifications

  • Dimensions 85 X 120 X 140mm
  • IP IP 20
  • Input voltage range 90 V-135 V (115 v ac) 170 V- 264 V (230 v ac)
  • Output Voltage 24 volt
  • Output Current 25 A
  • Input Current 8 A (115 Vac )- 4.2 A (230 Vac)
  • Efficiency ≥ 92 %
  • Number of phases 1

Price List

If you want to access to our price list, you should contact us:

Tel: +98 21 53815
Email: و

More Details

  • In case of short-circuit or overload, the output current is interrupted. In order to restart the output it is necessary to switch-off the input circuit for about 1 minute. This protection mode is particularly suggested in application where safety procedures require that reset be carried out only be an authorized person.
  • Hiccup mode
  • In case of short-circuit or overloading, the output current is interrupted. The device tries again to re-establish output voltage and normal condition about every 2 second till the problem is cleared.
  • Continuous output mode
  • In case of short –circuit or overload, the output current is kept at high values with near zero voltage. In case of short circuit the current can reaches up to 3 times the rated current at 60ºc. This protection mode is used to meet the requirements of demanding loads such as motors, solenoid valves, lamps, PLC with highly capacitive input circuits and other loads with marked transient overload behavior.