Protective Relay

Visits : 1331
Protective Relay

Protective relay is a device which is activated because of electrical quantity change such as volt and current or physical quantity like thermal degree and oil move and it leads to start other devices and at last break the circuit by circuit breaker . It is used for earth or air feeders in distribution system power plants in different voltage levels. It is used for protection of low or medium voltage engine in industry like power station and oil refinery in order to warranty engine function and its safety such as assurance about overload status. Main protection of transformer means counting (unit) differential protection which is unit protection. With regard to transformer function importance toward continuous electrification , power transformer protection has a great importance. impedance protection is used for protection of transmission, so that it is possible to discover the kilometer area that the error was happened in it. This kind of protection is mentioned as main protection of airlines. borna niroo karan company(Brnika) is the exclusive representative of Ziegler and Sprecher Automation Contrel on buying, selling, consulting services for automation systems and protective relays including protective relays .

Products

Single Phase Power Controller

Model: RP7 Order code: RP7-a b

Power controller RP7 type allows to control the delivered power from an a.c. voltage source to a resistance or resistance-inductive receiver of electrical energy and the rotational speed of 1-phase induction motors with a capacitor or commutator motors at small loads.

Show Detail

LUMEL Power Controller

Model: RP1 Order code: RP1-a b c

The RP1 power controller is destined for automatic temperature control systems in electrothermal devices.

Show Detail

Power Controller

Model: RPL1 Order code: RPL1- a b c dd e f

The area of RPL1 application includes: - electric furnaces and drying structures, especially industrial furnaces and tunnel cap, furnaces for annealing and brazing, and founder crucible furnaces, drying ovens, furnaces with quenching in salt baths; - mechanical engineering equipment, aggregates and extruders for plastics processing, winding machines and tempering springs, spot welding and linear; - production of glass and glazing, plant and equipment for drying in the infrared and ultraviolet, vats for melting glass and heating trays for forming glass furnaces; - chemical and petroleum industry; radiators lining piping, wiring warming

Show Detail

Three phase Power Controller

Model: RP3 Order code: RP3-a b

The RP3 power controller is a contactless three-phase power energy electronic device which includes a thyristor connector and an electronic gate triggering system. (GTS)

Show Detail

Multi differential protection relay

Model: MDR-2 Order code: MDR-2 No :2912500020-xx

The MDR-2 differential protection relay is a micro processor based control unit containing all necessary functions for monitoring of the differential currents for a synchronous/asynchronous generator or motor (the object). Via current transformers the MDR-2 measures each phase current on both sides of the object. The current transformers determine the limits of the protection area. Any failure within these limits (2- or 3-phase short circuits or earth leaks) will be detected as an error Id: Differential currents, the currents flowing through the two current transformers of the phase in question differ, and, if a preset limit value is exceeded, a warning will be given or a tripping signal transmitted. The MDR-2 dynamic compensation curves for warning and tripping are defined by the user.

Show Detail

Ziegler AC Current Protection Relay

Model: Model 252 , Model 253 Order code: 252-PAU , 252-PAO , 253-PAD , 253-PAV , 253-PAP

Current Protectors provide continuous surveillance of circuit . When the measured current the monitored moves outside the set point limit, the relay will operate . An adjustable time delay is provided to prevent the relay from tripping for a predetermined period to prevent nuisance tripping . For 3 phase systems , the sequence of connection is not important .

Show Detail

Ziegler AC Voltage Differential Relay

Model: AC Voltage Relay with adjustable Differential Order code: AC Voltage Relay with adjustable Differential

AC Voltage Differential Relay provides continuous surveillance of the monitored circuit . When the measured voltage moves outside the set point limit , the relay will operate giving an alarm and or initiation signal . An illuminated LED indicates when the relay is energised . The 3 Phase, 3 or 4 wire models protect each phase independently .

Show Detail

Voltage relay

Model: RMV-112D , RMV-122D , RMV-132D , RMV-142D Order code: RMV-1xxD No: 2913210yyy-zz

The protective voltage relays types RMV-112D, RMV-122D and RMV-132D form part of a complete DEIF series of relays for protection and control of generators and are applicable to both marine and land-based installations. Also available are voltage relays for single phase measurement (RMV-142D). The voltage relays are applied for protection of generators, motors and transformers against adverse system voltage conditions.

Show Detail

Frequency relay

Model: RMF-112D Order code: RMF-112D No :2913360120-xx

The digital, combined under-frequency and over-frequency relay type RMF-112D forms part of a complete DEIF series of relays for protection and control of generators. The relay is type-approved by major classification societies and is applicable to both marine and land-based installations. The RMF-112D is applied for protection against under-frequency and over-frequency by supervising the frequency (of generators) in single phase and 3-phase networks.

Show Detail

Ziegler AC Voltage Protection Relay

Model: AC Voltage Relay With Adjustable Time Delay Order code: AC Voltage Relay With Adjustable Time Delay

AC Voltage Protection Relay provide continuous surveillance of circuit . When the measured voltage the monitored moves outside the setpoint limit , the relay will operate after the selected time delay , giving an alarm and or initiation signal . Relays normally energise on over volts and de-energise on under volts . An illuminated indicates when the relay is LED energised . 3 phase 3 or 4 wire models protect each phase independently.

Show Detail

Ziegler Frequency Relay

Model: 252-PHU , 252-PHO , 253-PHD Order code: 252-PHU , 252-PHO , 253-PHD

frequency protectors provide continuous surveillance of the monitored circuit . When the frequency moves outside the set point limit, the relay will operate giving an alarm , control or tripping single . An illuminated LED indicates when the relay is energised.

Show Detail

Short Circuit Relay

Model: RMC-111D, RMC-122D, RMC-132D Order code: RMC-1xxD No:2913160yyy-zz

The protective current relays types RMC-111D, RMC-122D and RMC-132D form part of a complete DEIF series of relays for protection and control of generators. The relays are applicable to both marine and land-based installations. Also available are differential current relays (RMC-131D)

Show Detail