Combination surge arrester

Tags

Surge Arrester Combination Class B+C, Type I+II

On the base of standard, the gap between surge arrestor Class B and Class C installed, must not be less than 10 meters. Observe the distance, the problems that are created due to make the boards for fixing it, "Combination arrestor B+C" can be used. Some Class B arrestors have certain technology, that Class C arrestor can be installed immediately next to it.

View Details

Surge Arrester Combination Class C+D, Type II+III

On the base of standard, installed arrestor gap between Class C and Class D must not be less than 5 meters. Observe the distance, the problems that are created by the State Board for fixing, “Combination arrestor C+D“ can be used.

View Details

Cirprotec Combined surge arrester

Combined SPD - lightning current and surge arrester, Type 1+2 / Class I+II, 1 pole (1P), (L-N), 12.5 kA (10/350), 120 / 208 V, 1 module, pluggable.

View Details

2-poles surge arrester

Combined SPD - lightning current and surge arrester, Type 1+2 / Class I+II, 2 poles (1P+N), (L-N-PE), 12.5 kA (10/350), 120 / 208 V, TT earthing system, 2 modules, pluggable.

View Details

3-poles surge arrester

Combined SPD - lightning current and surge arrester, Type 1+2 / Class I+II, 3 poles (3P), (L1-L2-L3-PEN), 12.5 kA (10/350), 120 / 208 V, TNC earthing system, 3 modules, pluggable.

View Details

4-poles surge arrester

Combined SPD - lightning current and surge arrester, Type 1+2 / Class I+II, 4 poles (3P+N), (L1-L2-L3-N-PE), 12.5 kA (10/350), 120 / 208 V, TT earthing system, 4 modules, pluggable.

View Details

Replacement surge cartridge

Replacement surge cartridge for PSC, Type 1+2 / Class I+II, 1 pole, (1P), (L-N), 12.5 kA (10/350), 120 / 208 V, 1 module.

View Details

Replacement surge arrester cartridge

Replacement surge cartridge for PSC, Type 1+2 / Class I+II, 1 pole, (N), (N-PE), 50 kA (10/350), Neutral, 1 module.

View Details

Cirprotec CSC surge arrester

Combined SPD - lightning current and surge arrester, Type 1+2 / Class I+II, 1 pole (1P), (L-N), 7.5 kA (10/350), 120 / 208 V, 1 module, monobloc.

View Details

Surge arrester for Outdoor LED lighting

SPD Surge protection device, Type 2+3 / Class II+III, 2 poles, (L-N-GND), 10 kA (8/20), 230 / 400 V, aerial.

View Details

SPD type 2+3 with EMI filter

Combined SPD, Type 2+3 / Class II+III, EMI filter, 2 poles, 20 A gL, 20 kA (8/20), 6 kV (Uoc), 120 / 208 V, with remote indication.

View Details

Two pole surge protective device

Combined SPD, Type 2+3 / Class II+III, 2 poles, 20 kA (8/20), 10 kV (Uoc), 230 Vac, 1 module.

View Details