Surge Arrester Class C+D

Tags

Surge Arrester Combination Class C+D, Type II+III

On the base of standard, installed arrestor gap between Class C and Class D must not be less than 5 meters. Observe the distance, the problems that are created by the State Board for fixing, “Combination arrestor C+D“ can be used.

View Details

Surge arrester V10 COMPACT 150 OBO

Protection against lightning and severe vibration device, Class C + D , type II + III , high current conductivity and long life, with function display , suitable for TN, TT network systems , Arresting capacity to 10kA per pin (8/20) , With Maximum Continuous Operating Voltage (Uc=150V) , Appliction : industry , housing and device protection of rotary current sysrems .

View Details

Surge arrester V10 COMPACT 255 OBO

Protection against lightning and severe vibration device, Class C + D , type II + III , high current conductivity and long life, with function display , suitable for TN, TT network systems , Arresting capacity to 10kA per pin (8/20) , With Maximum Continuous Operating Voltage (Uc=255V) , Appliction : industry , housing and device protection of rotary current sysrems .

View Details

Surge arrester for Outdoor LED lighting

SPD Surge protection device, Type 2+3 / Class II+III, 2 poles, (L-N-GND), 10 kA (8/20), 230 / 400 V, aerial.

View Details

SPD type 2+3 with EMI filter

Combined SPD, Type 2+3 / Class II+III, EMI filter, 2 poles, 20 A gL, 20 kA (8/20), 6 kV (Uoc), 120 / 208 V, with remote indication.

View Details

Surge arrester V10 COMPACT 385 OBO

Protection against lightning and severe vibration device, Class C + D , type II + III , high current conductivity and long life, with function display , suitable for TN, TT network systems , Arresting capacity to 10kA per pin (8/20) . Appliction : industry , housing and device protection of rotary current sysrems . On the base of standard, installed arrestor gap between Class C and Class D must not be less than 5 meters. Observe the distance, the problems that are created by the State Board for fixing, “Combination arrestor C+D“ can be used.

View Details

Surge arrester V10COMPACT-AS OBO

Protection against lightning and severe vibration device, Class C + D , type II + III , high current conductivity and long life, with function display , suitable for TN, TT network systems , Arresting capacity to 20kA per pin (8/20) , Appliction : industry , housing and device protection of rotary current sysrems . On the base of standard, installed arrestor gap between Class C and Class D must not be less than 5 meters. Observe the distance, the problems that are created by the State Board for fixing, “Combination arrestor C+D“ can be used.

View Details

Surge arrester V10-C 3+NPE OBO

Protection against lightning and severe vibration device, Class C + D , type II + III , high current conductivity and long life, with function display , Arresting capacity to 10kA per pin (8/20) . Appliction : industry , equipotential bonding and device protection in main and subdistributors . On the base of standard, installed arrestor gap between Class C and Class D must not be less than 5 meters. Observe the distance, the problems that are created by the State Board for fixing, “Combination arrestor C+D“ can be used.

View Details

Surge arrester V10-C 3+NPE+FS OBO

Protection against lightning and severe vibration device, Class C + D , type II + III , high current conductivity and long life, with function display , Arresting capacity to 10kA per pin (8/20) , Appliction : industry , housing and device protection of rotary current sysrems . On the base of standard, installed arrestor gap between Class C and Class D must not be less than 5 meters. Observe the distance, the problems that are created by the State Board for fixing, “Combination arrestor C+D“ can be used.

View Details

Surge arrester V10-C 1+NPE-280 OBO

Protection against lightning and severe vibration device, Class C + D , type II + III , high current conductivity and long life, with function display , suitable for TN, TT network systems , Arresting capacity to 10kA per pin (8/20) , Appliction : industry , equipotential bonding and device protection in main and subdistributors . On the base of standard, installed arrestor gap between Class C and Class D must not be less than 5 meters. Observe the distance, the problems that are created by the State Board for fixing, “Combination arrestor C+D“ can be used.

View Details

Surge arrester V10-C/1-280 OBO

Protection against lightning and severe vibration device, Class C + D , type II + III , high current conductivity and long life, with function display , suitable for TN, TT network systems , Arresting capacity to 10kA per pin (8/20) . On the base of standard, installed arrestor gap between Class C and Class D must not be less than 5 meters. Observe the distance , the problems that are created by the State Board for fixing, “Combination arrestor C+D“ can be used.

View Details

Two pole surge protective device

Combined SPD, Type 2+3 / Class II+III, 2 poles, 20 kA (8/20), 10 kV (Uoc), 230 Vac, 1 module.

View Details