Related tags for:

سرج ارستر

Surge Arrestrer
  • Arresters in electrical networks to protect equipment against damage caused by sudden over voltage such as lightning and thunder is used .
  • Details ...
Combination arrestor PS3-B+C-320 OBO
  • combination arrester three-phase protection, as you know, On the base of standard, the gap between surge arrestor Class B and Class C installed, must not be less than 10 meters. Observe the distance, the problems that are created due to make the boards for fixing it, "Combination arrestor B+C" can be used. Some Class B arrestors have certain technology, that Class C arrestor can be installed immediately next to it.
  • Details ...
Combination arrestor PS3-B+C TNC+FS OBO
  • as you know ,On the base of standard, the gap between surge arrestor Class B and Class C installed, must not be less than 10 meters. Observe the distance, the problems that are created due to make the boards for fixing it, "Combination arrestor B+C" can be used. Some Class B arrestors have certain technology, that Class C arrestor can be installed immediately next to it.
  • Details ...
Combination arrestor PS3-B+C-320+FS OBO
  • combination arrester , three-phase protection , with remote signalling . On the base of standard, the gap between surge arrestor Class B and Class C installed, must not be less than 10 meters. Observe the distance, the problems that are created due to make the boards for fixing it, "Combination arrestor B+C" can be used. Some Class B arrestors have certain technology, that Class C arrestor can be installed immediately next to it.
  • Details ...
Combination arrestor PS4-VA TT+TNS OBO
  • combination arrester three-phase + neutral protection . On the base of standard, the gap between surge arrestor Class B and Class C installed, must not be less than 10 meters. Observe the distance, the problems that are created due to make the boards for fixing it, "Combination arrestor B+C" can be used. Some Class B arrestors have certain technology, that Class C arrestor can be installed immediately next to it.
  • Details ...
Combination arrestor PS4-VA TT+FS OBO
  • combination arrester , three-phase + neutral protection , with remote signalling, no leakage current On the base of standard, the gap between surge arrestor Class B and Class C installed, must not be less than 10 meters. Observe the distance, the problems that are created due to make the boards for fixing it, "Combination arrestor B+C" can be used. Some Class B arrestors have certain technology, that Class C arrestor can be installed immediately next to it.
  • Details ...
Combination arrestor PS3-VA TNC OBO
  • combination arrester , three-phase protection,leakage current-free , On the base of standard, the gap between surge arrestor Class B and Class C installed, must not be less than 10 meters. Observe the distance, the problems that are created due to make the boards for fixing it, "Combination arrestor B+C" can be used. Some Class B arrestors have certain technology, that Class C arrestor can be installed immediately next to it.
  • Details ...
Surge arrester V20-C 3+NPE-280 OBO
  • As the second phase of the protection circuit is used and the ability to resist a sudden flow of 120 kA with wave form 8/20 μs to have repetitions. The equipment in the power distribution (power), power dividers and sub-distributors are installed.
  • Details ...
Combination arrestor PS3-VA TNC+FS OBO
  • combination arrester , three-phase protection , with remote signalling, leakage current-free . On the base of standard, the gap between surge arrestor Class B and Class C installed, must not be less than 10 meters. Observe the distance, the problems that are created due to make the boards for fixing it, "Combination arrestor B+C" can be used. Some Class B arrestors have certain technology, that Class C arrestor can be installed immediately next to it.
  • Details ...
Combination arrestor V25-B+C 1+FS-280 OBO
  • combination arrestor , with a visual representation of performance , with remote signalling . On the base of standard, the gap between surge arrestor Class B and Class C installed, must not be less than 10 meters. Observe the distance, the problems that are created due to make the boards for fixing it, "Combination arrestor B+C" can be used. Some Class B arrestors have certain technology, that Class C arrestor can be installed immediately next to it.
  • Details ...
Page 1 Of 12