Related tags for:

Synchronization

Complete Set of Synchronized
  • Complete set of synchronized includes: - Electronic Synchroscope - Double Voltmeter - Double Frequency meter .
  • Details ...
Synchroscope
  • The Electronic Synchroscope is designed to provide an illuminated indication of actual phase difference between the BUS Voltage(reference voltage) the GENERATOR Voltage(incoming & voltage) . When two alternators are paralleled it is necessary that ,1-Frequency must be equal . 2-Phase must be same .
  • Details ...
LED Synchroscope
  • The Electronic Synchroscope is designed to provide an illuminated indication of actual phase difference between the BUS Voltage(reference voltage) the GENERATOR Voltage(incoming & voltage) . this device has three potentiometer to adjust the phase difference , the voltage and time synchronization . When two alternators are paralleled it is necessary that ,1-Frequency must be equal . 2-Phase must be same .
  • Details ...
Analoge Double Voltmeter
  • 2 in 1 pointer type analoge panel meter come in 96 mm × 96 mm size. These measure AC current & voltage depending upon the application. These combine two measuring systems independent of each other . The double voltmeter to measure the voltage of two different sources in order to are use to synchronize these two sources .
  • Details ...
Analog Panel Double Voltmeter
  • Enerdis Analog Panel Double Voltmeter in the form of polycarbonate and in size of 96 mm for synchronizing operations or displays two input voltage in one panel .
  • Details ...
Synchronizer control and load sharing equipments
  • To connect two different power sources with each other, before connecting the switch, synchronizing between two sources should be checked; Otherwise the switch and resource will be injured . This equipment is used to synchronize the two sources .
  • Details ...
Analog Synchroscope
  • The Electronic Synchroscope is designed to provide an illuminated indication of actual phase difference between the BUS Voltage(reference voltage) the GENERATOR Voltage(incoming & voltage) . When two alternators are paralleled it is necessary that ,1-Frequency must be equal . 2-Phase must be same .
  • Details ...
Ziegler SQ LED Synchroscope
  • The Electronic Synchroscope is designed to provide an illuminated indication of actual phase difference between the BUS Voltage(reference voltage) the GENERATOR Voltage(incoming & voltage) . When two alternators are paralleled it is necessary that ,1-Frequency must be equal . 2-Phase must be same .
  • Details ...
Digital Synchronizer
  • For testing the status of synchronism of the two networks and licensing switch connection of synchro-check relay and is using for synchronizing a generator with the synchronizer relay.
  • Details ...
Enerdis Synchro Coupler Synchronoscope
  • The SYNCHRO COUPLER is an automatic synchronization instrument for generator: sets it includes a control relay for assisted time delay control pling with manual coupling or automatic coupling .two control relays (fast/slow) for speed adjustment . an external control loop for opening the coupling relay . four front panel keys for programming , option included(display and messages ) password .
  • Details ...
Page 1 Of 2