Synchronization

Tags

Complete Set of Synchronized

Complete set of synchronized includes: - Electronic Synchroscope - Double Voltmeter - Double Frequency meter .

View Details

Ziegler SQ LED Synchroscope

The Electronic Synchroscope is designed to provide an illuminated indication of actual phase difference between the BUS Voltage(reference voltage) the GENERATOR Voltage(incoming & voltage) . When two alternators are paralleled it is necessary that ,1-Frequency must be equal . 2-Phase must be same .

View Details

LED Synchroscope

The Electronic Synchroscope is designed to provide an illuminated indication of actual phase difference between the BUS Voltage(reference voltage) the GENERATOR Voltage(incoming & voltage) . this device has three potentiometer to adjust the phase difference , the voltage and time synchronization . When two alternators are paralleled it is necessary that ,1-Frequency must be equal . 2-Phase must be same .

View Details

Analoge Double Voltmeter

2 in 1 pointer type analoge panel meter come in 96 mm × 96 mm size. These measure AC current & voltage depending upon the application. These combine two measuring systems independent of each other . The double voltmeter to measure the voltage of two different sources in order to are use to synchronize these two sources .

View Details

Analog Panel Double Voltmeter

Enerdis Analog Panel Double Voltmeter in the form of polycarbonate and in size of 96 mm for synchronizing operations or displays two input voltage in one panel .

View Details

Analog Synchroscope

The Electronic Synchroscope is designed to provide an illuminated indication of actual phase difference between the BUS Voltage(reference voltage) the GENERATOR Voltage(incoming & voltage) . When two alternators are paralleled it is necessary that ,1-Frequency must be equal . 2-Phase must be same .

View Details

Digital Synchroscope

For testing the status of synchronism of the two networks and licensing switch connection of synchro-check relay and is using for synchronizing a generator with the synchronizer relay.

View Details

Enerdis Synchro Coupler Synchronoscope

The SYNCHRO COUPLER is an automatic synchronization instrument for generator: sets it includes a control relay for assisted time delay control pling with manual coupling or automatic coupling .two control relays (fast/slow) for speed adjustment . an external control loop for opening the coupling relay . four front panel keys for programming , option included(display and messages ) password .

View Details

Enerdis PID Synchro Coupler Synchronoscope

The PID Synchro Coupler is an automatic synchronization instrument for generator and LV networks : sets it includes a control relay for assisted time delay control pling with manual coupling or automatic coupling . two control relays (fast/slow) for speed adjustment . an external control loop for opening the coupling relay . four front panel keys for programming , option included(display and messages ) password .

View Details

Surge arrester V20-C 2+NPE-280 OBO

As the second phase of the protection circuit is used and the ability to resist a sudden flow of 60 kA with wave form 8/20 μs to have repetitions. The equipment in the power distribution (power), power dividers and sub-distributors are installed.

View Details

Check Synchronising Relay

The CSQ-3 is a microprocessor-based synchronising unit. It can be used in any kind of installation where manual or semi-automatic synchronising is required. Two versions optimised for land or marine applications exist. The unit measures the busbar (UBUSBAR) and generator (UGEN) voltages and frequencies and compares these, plus compares the phase angle relationship.

View Details

Read Synchroscope

The RSQ-3 is a microprocessor-based synchronising unit, providing visual indication of relevant values for synchronising a generator to a net (busbar). It can be used in any kind of installation where manual synchronising is required. The unit measures the busbar (UBUSBAR) and generator (UGEN) voltages and frequencies and compares these, plus compares the phase angle relationship.

View Details