Surge Arrestrer

Visits : 1619
Surge Arrestrer

Arresters in electrical networks to protect equipment against damage caused by sudden over voltage such as lightning and thunder is used . Bornika is the exclusive agent of OBO Bettermann and iskra in the fields of consulation, sales and distribution of power industry products and surge arrester including Class B, Combination B+C, Class C, Combination C+D, Class D, solar batteries, phone lines, coaxial cable , network cables, explosion-proof Barrier & Spark Gaps, Surge Arrestor's Counter and lightning arrester,data network,coupling earthing systems,earth terminal or load trminal ,measurement Relays of ground resistance,

Products

Surge arrester MC 50-B-OS OBO

Model: MC, 255V for TN Networks Order code: 5096851

Lightning , protection of single-phase , with a visual representation of performance , as a first step that can be used in the protection circuit currents up to 50kA with waveform 10 / 350μS to move out . at the entrance of the building, before or after the meter or main distribution boards installed .

Show Detail

Surge arrester MC 50-B 3+1 OBO

Model: MC, 255V for TN-S/TT Networks Order code: 5096878

Lightning , Three-phase + neutral protection , as a first step that can be used in the protection circuit currents up to 125kA with waveform 10 / 350μS to move out . at the entrance of the building, before or after the meter or main distribution boards installed .

Show Detail

Spark gaps MC 125-B NPE OBO

Model: MC, 255V for TN-S/TT Networks Order code: 5096863

Lightning , single-phase protection , as a first step that can be used in the protection circuit currents up to 125kA with waveform 10 / 350μS to move out . at the entrance of the building, before or after the meter or main distribution boards installed.

Show Detail

Surge arrester MC 50-B 3 OBO

Model: MC, 255V for TN Networks Order code: 5096876

Lightning , Three-phase protection , as a first step that can be used in the protection circuit currents up to 150kA with waveform 10 / 350μS to move out . at the entrance of the building, before or after the meter or main distribution boards installed.

Show Detail

Surge arrester MC 50-B VDE OBO

Model: MC, 255V for TN Networks Order code: 5096847

Lightning , protection of single-phase , as a first step that can be used in the protection circuit currents up to 50kA with waveform 10 / 350μS to move out . at the entrance of the building, before or after the meter or main distribution boards installed.

Show Detail

Surge arrestor MCD 50-B 3+1 OBO

Model: MCD, 255V for TN-S/TT Networks Order code: 5096879

Lightning , Three-phase + neutral protection , as a first step that can be used in the protection circuit currents up to 125kA with waveform 10 / 350μS to move out . at the entrance of the building, before or after the meter or main distribution boards installed.

Show Detail

Combination arrestor MCD 50-B 3+1-OS OBO

Model: MCD, 255V for TN-S/TT Networks Order code: 5096836

Lightning , Three-phase + neutral protection , with function display , as a first step that can be used in the protection circuit currents up to 125kA with waveform 10 / 350μS to move out . at the entrance of the building, before or after the meter or main distribution boards installed.

Show Detail

Combination arrestor MCD 125-B NPE OBO

Model: MCD, 255V for TN-S/TT Networks Order code: 5096865

Lightning , single-phase protection , as a first step that can be used in the protection circuit currents up to 125kA with waveform 10 / 350μS to move out . at the entrance of the building, before or after the meter or main distribution boards installed.

Show Detail

Combination arrestor MCD 50-B 3 OBO

Model: MCD, 255V for TN Networks Order code: 5096877

Lightning , Three-phase protection , as a first step that can be used in the protection circuit currents up to 150kA with waveform 10 / 350μS to move out . at the entrance of the building, before or after the meter or main distribution boards installed.

Show Detail

Combination arrestor MCD 50-B 3-OS OBO

Model: MCD, 255V for TN Networks Order code: 5096835

Lightning , Three-phase protection , with function display , as a first step that can be used in the protection circuit currents up to 150kA with waveform 10 / 350μS to move out . at the entrance of the building, before or after the meter or main distribution boards installed.

Show Detail

Combination arrestor MCD 50-B OBO

Model: MCD, 255V for TN Networks Order code: 5096849

Lightning , single-phase protection , as a first step that can be used in the protection circuit currents up to 50kA with waveform 10 / 350μS to move out . at the entrance of the building, before or after the meter or main distribution boards installed.

Show Detail

Combination arrestor MCD 50-B-OS OBO

Model: MCD, 255V for TN Networks Order code: 5096852

Lightning , single-phase protection , with function display , as a first step that can be used in the protection circuit currents up to 50kA with waveform 10 / 350μS to move out . at the entrance of the building, before or after the meter or main distribution boards installed.

Show Detail