Current Shunt

Visits : 589
Current Shunt

DC shunts convert high value current in DC circuits into proportional voltage drop (50mV/60mV/75mV/150mV) which can be connected of DC voltmeters to measure the high value current. Form A : Insulating base mounted shunts clamping to DIN mounting rail or wall mounting (upto 30A) without insulating base (31...150A) , High conductivity brass Form B : L-profile end blocks , High conductivity brass / copper Form C : High conductivity brass / copper Base material : Polycarbonate Accuracy class : Class 1, 0.5, 0.2 (Optional) Bornika is the exclusive agent of Ziegler, Lumel, Enerdis company in fields of consultation, sales and distribution of power industry products including DC Shunts .

Products

DC Shunts

DC shunts convert high value current in DC circuits into proportional voltage drop (50mV/60mV/75mV/150mV) which can be connected of DC voltmeters to measure the high value current.

Show Detail

Enerdis DC current shunt

Enerdis DC current shunt used for measuring high currents in DC networks. enerdis shunts are available in five following models: 76-2:with Eye connection, Eye connection on base 77-2: with Plate connection for busbar SHMI: with Screw, Eye and to block for busbar connection SHEL: with Direct connection to measuring component Enerdis DC shunts are available in 1A to 6000A with voltage drops: 50 mV - 60 mV - 100 mV - 150 mV - 200 mV - 300 mV - 1 V

Show Detail

DC Shunt

Measuring shunts B2 type are destined to extend measuring ranges of d.c. ammeters, wattmeters and electrodynamic or ferrodynamic counters which accuracy classes are: 1, 1.5, or 2.5

Show Detail

Shunt Resistor

Measuring shunts B3 type are destined to extend measuring ranges of d.c. ammeters, wattmeters and electrodynamic or ferrodynamic counters which accuracy classes are: 1, 1.5, or 2.5

Show Detail

LUMEL Shunt Resistor

Measuring shunts B4 type are destined to extend measuring ranges of d.c. ammeters, wattmeters and electrodynamic or ferrodynamic counters which accuracy classes are: 1, 1.5, or 2.5

Show Detail

DC Shunt Resistor

Measuring shunts B5 type are destined to extend measuring ranges of d.c. ammeters, wattmeters and electrodynamic or ferrodynamic counters which accuracy classes are: 1, 1.5, or 2.5

Show Detail

100 mV Shunt

Measuring shunts B6 type are destined to extend measuring ranges of d.c. ammeters, wattmeters and electrodynamic or ferrodynamic counters which accuracy classes are: 1, 1.5, or 2.5

Show Detail

Shunt Resistor

Shunts provide an accurate DC milivolt signal to drive moving-coil ammeters, overload protection and control units for higher ampere range. Shunt Resistors introduced by two generally type as 60 and 150 mV. Type 60 mV divided into A and B form. Also , Type 150mV divided into Three form as A , B and C.

Show Detail