Rail Mounted Power Analyzer

N43- a b c d ee f g

    • Model
    • N43

    • Order code
    • N43- a b c d ee f g

    • Country
    • Poland
  • Rail Mounted Power Analyzer model N43 Destined for direct (up to 63A) and indirect measurements in 3 phase 4 wire/3 wire balanced and unbalanced systems. Features: - the measurement of: rms values of voltage and current, active, reactive and apparent power, active, reactive energy, power factors, frequency THD - indications considering values of programmed ratios, - programmable current and voltage ratios, - 12 programmable screens/pages, - backlit LCD display, - digital transmission to the master system through the RS-485 interface with Modbus protocol, - configurable alarm outputs, - the pulse output for monitoring of 3-phase active energy, - analog outputs are available by connecting S4AO module, - USB for configuration by using free eCon software, - implemented function for software updating, - modern design allows for installation of the meter in modular switchgear in accordance with EN 62208, (meter has a width of 6 modules) on 35 mm rail, - external dimensions: 105 x 110 x 60mm Borna Niroo Karan (Bornika) is the exclusive agent of LUMEL in the fields of consultation , sales and distribution of power industry products including Rail Mounted Power Analyzer products .

  • Visits: 0
Downloads
Related products
Specifications
    • Input Range
    • Current In : 1 A ~ : 0.002...1.20 A or kA * 5 A ~ : 0.010...6.00 A or kA * 63 A ~ : 0.10...76.0A Voltage L-N : 57,7 V ~ : 2.80 ...70.0 V or kV* 230 V ~ : 10.0 ... 276 V~ 290 V ~: 14.0 ... 348 V~ Voltage L-L : 100 V ~ : 5.00 ... 120 V or kV* 400 V ~ : 20.0 ... 480 V~ 500 V ~ : 25.0 ... 600 V~ Frequency : 47.0 ... 63.0 Hz Active power : 0.00 ... 999 W, kW or MW Reactive power : 0.00 ... 999 VAR, kVAr or MVAr Apparent power : 0.00 ... 999 VA, kVA or MVA Active energy : 0.0 ... 999999.9 kWh or MWh Reactive energy : 0.0 ... 999999.9 kVArh or MVArh Power factor PF : -1 ... 0 ... 1 Tangent PHI : -1.2 ... 1 ...1.2

    • Power Supply
    • 85...253 V a.c., 90...300 V d.c. 20...40 V a.c., 20...60 V d.c.

    • IP
    • IP50

    • Dimensions
    • 105x110x60 mm

More details
  • Ordering code:
  • Ordering Code N43- a b c dd e f : a :Current input In: 1 A/5 A (X/1; X/5) : 1 63 A : 2 b : Voltage input (phase/ phase-to-phase) Un: 3 x 57.7/100 V : 1 3 x 230/400 V : 2 3 x 290/500 V : 3 c : Auxiliary supply: 85...253 V a.c., 90...300 V d.c. : 1 20...40 V a.c., 20...60 V d.c. : 2 dd: Version: standard : 00 custom-made : XX e : Language: Polish : P English ; E f : Acceptance tests: without extra quality requirements : 0 with an extra quality inspect on certificate : 1
  • Outputs:
  • Relay output : 3x programmable relay output, normally open voltageless contacts, load capacity 250 V~/0.5 A~ Pulse output : 1 x pulse output, OC type, passive (for monitoring of active energy)
Applications
  • Refinery

  • Power industry

  • Petrochemical industry

  • Automotive industry

  • Military and defense industry

  • Oil and gas industry

  • Power Plant industry

  • Panel building companies

  • Steel industry

  • Instrumentation Companies

  • Education and Laboratory industry

  • Engineering services industry

  • Railway and subway industry

  • Science and Technology Education

  • Automation industry

  • Charger, inverter and converters manufacturers

  • Cathodic protection companies

  • Transformer manufacturing companies

Prices