Paralleling relay

HAS-111DG No: 2913020060 -xx

    • Model
    • HAS-111DG

    • Order code
    • HAS-111DG No: 2913020060 -xx

    • Country
    • Denmark
  • The HAS-111DG synchroniser is applied to check the synchronisation conditions. The paralleling relay transmits a synchronisation pulse when the phase angle, frequency and voltage deviations are within the set limits. Besides this, the HAS-111DG is equipped with two analogue outputs. These outputs can be used for regulating purposes together with DEIF A/S load sharing units. Function : The HAS-111DG can be used in installations where manual or semi-automatic synchronising is required, or by using the ∆f and/or the ∆U output for automatic synchronisation of a generator island to another utility . Settings : The HAS-111DG is equipped with five potentiometers accessible from the front of the unit. Phase: Here the phase window for synchronisation is chosen. It can be set symmetrically or asymmetrically. Frequency: Here the max. slip frequency difference is chosen. It can be set both symmetrically and asymmetrically around 0 Hz. Voltage: Here the allowed voltage difference between UGEN and UBUSBAR is chosen. It can be set symmetrically. The HAS-111DG measures the busbar and generator voltages in order to obtain data on frequency, phase and voltage deviation. A synchronising signal is transmitted when the following conditions are fulfilled: 1. The voltage difference is within ±2 to ±12 % of the busbar voltage set on the VOLTAGE potentiometer, and 2. the frequency difference ∆f is within -1 to 0 Hz and 0 to 1 Hz of the values set on the FREQUENCY potentiometers, and 3. the phase angle difference is within -25 to -5 ° el. and 5 to 25 ° el. of the value set on the PHASE potentiometers, and 4. the ∆f allows a synchronisation pulse of min. 100 ms without exceeding the setting of the PHASE potentiometers. When the above four conditions are fulfilled, a synchronising signal is transmitted and the yellow SYNC LED is lit. The pulse length (100 ms to 3 s) depends on the other settings of the relay. Features : - Synchronisation of generator to busbar - Setting of phase angle difference - Setting of frequency and voltage diff. - LED indication of status - LED for synchronising signal - 35 mm DIN rail or base mounting Borna Niroo Karan (Bornika) is the exclusive agent of DEIF in the fields of consultation , sales and distribution of power industry products including Paralleling relay products .

  • Visits: 50
Downloads
Specifications
    • Input Voltage
    • Meas. voltage: 57.7-63.5-100-110-127-200-220-230-240-380-400-415-440-450-480-660-690 V AC

    • Frequency Range
    • 40 to 45 to 65 to 70 Hz

    • Accquracy
    • Breaker closing: Slip frequency 0 Hz: ±2 ° el. Slip frequency 0.1 to 0.5 Hz: ±3 ° el. Slip frequency 0.5 to 1 Hz: ±5 ° el.

    • Power Supply
    • Supply voltage (Un): 57.7-63.5-100-110-127-220-230-240-380-400-415-440-450-480-660-690 V AC ±20 % (max. 3.5 VA) 24-48-110-220 V DC -25/+30 % (max. 2.5 W)

    • IP
    • IP40

More details
  • Ordering code:
  • Ordering Code HAS-113DG No:2913020060-xx : xx : 01 : DC supply 02 : AC supply
  • Analogue output:
  • Freq. difference: 1 analogue output: -10 to 0 to 10 V DC ~ -5 to 0 to 5 Hz Volt. difference: 1 analogue output: 0 to 5 to 10 V DC ~ 80 to 100 to 120 % of Un -10 to 0 to 10 V DC ~ 90 to 100 to 110 % of Un with option E activated
  • Optocoupler output:
  • Max. voltage : 30 V DC, max. current : 5 mA
  • Digital input:
  • Potential-free contact : Open: 5 V. Closed: 5 mA
Applications
  • Refinery

  • Power industry

  • Petrochemical industry

  • Marine and shipbuilding industry

  • Military and defense industry

  • Oil and gas industry

  • Power Plant industry

  • Panel building companies

  • Instrumentation Companies

  • Education and Laboratory industry

  • Engineering services industry

  • Railway and subway industry

Prices