Insulation transducer for non-ground AC networks MCM165x

MCM165x

    • Model
    • MCM165x

    • Order code
    • MCM165x

    • Country
    • Norway
  • The digitally controlled MCM165x series monitors insulation level between a non-grounded (IT) AC mains and its protective earth, regardless of whether the mains is live or non-live (standby). An AC or DC auxiliary voltage is required for the unit, if powered from a separate source the network can also be monitored during standby conditions. Only ONE MCM165x can be connected to each IT-system. The unit injects a sequentially coded measuring signal into the monitored system. The signal flows to ground via the path of the insulation fault, the level of flow indicates the insulation resistance. The measuring accuracy is not influenced by any normal kind of load attached to the AC network. Features: -Direct connection up to 690V line voltage, up to 25kV with HV adapter -Monitoring during both live and standby conditions -For use in land, marine, offshore, sub-sea and ocean floor Installations -Comply with AODC 035 Code of Practice -"Megger" - safe to 1,4kVDC when aux power is OFF -Immune to earth capacitance and voltage surges -Analogue output proportional to meter reading -Optional slave indicator Borna niroo karan company (Brnika) is Exclusive Representative of Megacon , in the purchase, sales, consulting and distribution and industrial equipment and measurement equipment, including Insulation Monitoring and so is active .

  • Visits: 7
Downloads
Specifications
    • Power Supply
    • 100-120, 200-240, 380-415 or 440-460VAC, 40-70Hz (Fuse 0.5A) 12-24, 48 or 110VDC (Fuse 2A)

    • Output
    • Analogue Output: Up to 20mA, max 500R Up to 10V, min 100kohm (other on request)

    • Operating Temperature
    • -20 to +70ºC

    • Approximate Weight
    • 0.5kg

    • IP
    • IP21

More details
  • scale description :
  • The ohmmeter and the triple-zone status LEDs give at a glance the clear safetymessage: -ALARM(red zone) -WARNING(yellow zone) -HEALTHY(green zone )
  • High Voltage Adaptors up to 25kVAC for MCM165x series:
  • Voltage Adaptors ARx and ANx are used together with Insulation Guard MCM165x when the monitored line voltage is higher than 690VAC. AR7 up to 7kVAC AR14 up to 14kVAC AN7 up to 7kVAC AN14 up to 14kVAC AN25 up to 25kVAC
  • Caution:
  • Terminal 1must be disconnected during ’’megger’’test.
Applications
  • Refinery

  • Electronics industry

  • Power industry

  • Marine and shipbuilding industry

  • Road Construction industry

  • Military and defense industry

  • Oil and gas industry

  • Power Plant industry

  • Panel building companies

  • Steel industry

  • Instrumentation Companies

  • Engineering services industry

  • Railway and subway industry

  • Meteorological industry

  • Cathodic protection companies